SEC MilleniumMillenium Carbon Dioxide
Gas Detector
Instruction and Operation Manual
Part Number 71-5000 Version 100201
Vedere la pagina 0
1 2 3 4 5 6 ... 12 13

Sommario

Pagina 1 - Gas Detector

SEC MilleniumMillenium Carbon Dioxide Gas Detector Instruction and Operation Manual Part Number 71-5000 Version 100201

Pagina 2

9 VI. Parts List Part Number Description 142-0617 Replacement Sensor SEC MILLENIUM (Specify range when ordering) 190-1001 SEC 2001 Sensor Sep

Pagina 3 - Table of Contents

10 VII. Drawing Section Figure # Title Figure 1 Wiring Diagram, SEC MILLENIUM Figure 2 SEC Sensor Separation Kit

Pagina 4 - I. SPECIFICATIONS

11 WIRING DIAGRAM MILLENIUM SENSOR FIGURE 1 WHITE: Calibration/Data RED: +24 VDC BLACK: -24VDC (DC Common) BLUE: 4 TO 20 mA Out OutOUTPUT 6.5

Pagina 5 - VDC (DC Voltage)

12 WIRE ENTRY FOR SENSOR 3/4 NPT WIRE ENTRY FOR RETURN TO SEC 3100 3/4 NPT NOTE: HOUSING RATED FOR CLASS 1, DIV 1, GROUPS B, C AND D SEC SENSO

Pagina 6

(SEC) designs and manufactures innovative fixed system gas detection equipment, for combustible gases, oxygen, carbon dioxide and toxic gases

Pagina 7 - III. OPERATION

Table of Contents I. SPECIFICATIONS II. GENERAL DESCRIPTION III. OPERATION Installation and Startup IV. CALIBRATION V. MAI

Pagina 8

3 I. SPECIFICATIONS Model: SEC MILLENIUM Infrared Carbon Dioxide (CO2) Gas Detector Part Number: 142-0617 Specify range when ordering Detect

Pagina 9 - V. MAINTENANCE

4 II GENERAL DESCRIPTION CONVENTIONS The following conventions are used in this manual. Warning Statement VDC (DC Voltage

Pagina 10 - VI. Parts List

5 Infrared Absorption Spectrum for Carbon Dioxide The dual channel receiver is a single wafer, double filtered, dual receiver with an intern

Pagina 11 - VII. Drawing Section

6 III. OPERATION Installation and Startup Warning: The user shall be made aware that if the equipment is used in a manner not specified by the m

Pagina 12 - FIGURE 1

7 Warm-up When power is applied to the detector, it enters a one (1) minute warm-up mode. The output current will be 0.8 mA during the warm up ti

Pagina 13 - FIGURE 2

8 IV. CALIBRATION SEC MILLENIUM The SEC MILLENIUM is factory calibrated zeroed and spanned. Unlike other types of sensors it does not requir